Integrations & protocol compatibility

Meshkindle is not a BMS replacement. It adds a wireless sensor layer that integrates directly into the Johnson Controls, Siemens, and Honeywell platforms your facility team already operates — via native BACnet/IP and Modbus TCP, no middleware required.

View Integration Matrix

Compatibility Matrix

Protocol compatibility matrix

All protocols supported natively on the MK-GW-1000 gateway. No additional licenses or middleware servers required.

Protocol / Standard Direction Gateway support Use case
BACnet/IP (ASHRAE 135)BMS polling mesh dataNative — no licenseBMS sensor integration, HVAC setpoints
Modbus TCP (IEC 61158)SCADA polling mesh dataNative slave modeChiller/boiler/AHU control registers
MQTT (v3.1.1 / v5)BidirectionalBuilt-in broker + bridgeCustom IoT dashboards, cloud platforms
MQTT-SNMesh sensor → gatewayBuilt-inLow-power Thread/Zigbee sensor data
CoAP (RFC 7252)Mesh sensor → gatewayBuilt-inThread sensor telemetry (low overhead)
DALI-2 (IEC 62386)Gateway → luminairesVia MK-NODE-BTLighting zone control, dimming
KNX/IPGateway → BMSKNXnet/IP tunnelingEuropean BMS installations
REST API (JSON/HTTPS)BidirectionalMeshOS v2+CMMS integration, custom dashboards
6LoWPAN / IPv6Thread meshBorder Router on GWIPv6-native device addressing
LoRaWAN (LoRa Alliance)BidirectionalOptional moduleOutdoor sensors, parking, long-range

BMS Partners

Building Management Systems

Integration-tested configurations for the major BMS platforms found in commercial and institutional buildings.

Johnson Controls Metasys

BACnet/IP primary. N2 bus adapter available for legacy installations. Tested with NAE55, NCE25, FEC16 field controllers. Point mapping tool provided.

Siemens Desigo CC

BACnet/IP via Desigo CC BACnet driver. Tested with PXM50 building automation station. OPC UA bridge available for Desigo Insight integrations.

Honeywell Niagara 4

BACnet + Modbus TCP via standard Niagara drivers. Node-RED flows available for custom logic. Tested with JACE-8000 and WEBstation-AX.

Schneider Electric EcoStruxure

BACnet/IP integration. MQTT bridge to EcoStruxure IT Expert via cloud connector. Tested with SmartX IP controllers.

ABB Ability

Modbus TCP slave mode. MQTT bridge to ABB Ability platform. Contact for configuration guide.

Custom / Open Systems

REST API (JSON/HTTPS) for full programmatic access. MQTT broker bridge for any MQTT-compatible IoT platform. All integrations are customer-buildable.

REST API

Build your own integration

If your BMS isn't on the list above, the MeshOS REST API provides full access to node inventory, sensor readings, alert rules, and OTA management. OAuth 2.0 bearer token authentication.

Base URL: https://<gateway-ip>/api/v1/

Request API Documentation
Node API

Inventory, status, sensor reads

OTA API

Firmware trigger, progress

Alert API

Rules, history, webhooks

Export API

Historical data CSV/JSON

Not sure if your BMS is compatible?

Send us your BMS model and firmware version. We'll confirm compatibility before the pilot starts.